INCH-POUND
MIL-DTL-6396F
28 July 2008
SUPERSEDING
MIL-T-6396E
30 August 1983
DETAIL SPECIFICATION
TANKS, FUEL, OIL, COOLING FLUIDS, INTERNAL, REMOVABLE
NON-SELF-SEALING
This specification is approved for use by all Departments and Agencies of the Department of
Defense.
1. SCOPE
1.1 Scope. This specification covers internal, removable, non-self-sealing tanks, including
tank fittings for use on aircraft.
1.2 Classification. The tanks are of the following general types, as specified (see 6.2).
1.2.1 Types. The types of tanks are as follows:
Type I - Metallic.
Type II Non-metallic, bladder, flexible cell construction.
Class A Continuously supported.
Class B Continuously supported tear resistant.
Class C Intermittently supported.
Type III Non-metallic, rigid/non-flexible, self-supporting cell construction.