MIL-STD-801D
TABLE III. Additional criteria for stand tested fuel cells fuel cell finishing operations. 1/
Item |
Defects |
Defect Classes |
Types of Fuel Cells |
||||
Minor |
Major |
Critical |
Bladder Cells |
Self- sealing Cells |
Crash Resistant Cells |
||
1 |
STAIN OR ACTIVATION DUE TO DETERIORATION OF CELL 2/ |
- |
- |
x |
x |
x |
x |
2 |
STAIN OR ACTIVATION DUE TO DESIGN FAILURE 2/ |
- |
- |
x |
x |
x |
x |
3 |
STAIN OR ACTIVATION DUE TO MANUFACTURING DEFECT 2/ |
- |
- |
x |
x |
x |
x |
4 |
STAIN OR ACTIVATION DUE TO MISHANDLING OR REWORK DAMAGE 2/ |
- |
- |
x |
x |
x |
x |
5 |
STAIN OR ACTIVATION DUE TO MISHANDLING OR IMPROPER CELL 2/ |
||||||
a. Condition of cell does not preclude complete evaluation of cell. |
no defect |
- |
- |
x |
x |
x |
|
b. Condition precludes complete evaluation. |
retest |
- |
- |
x |
x |
x |
|
6 |
ACTIVATION ANYWHERE IN THE CELL |
- |
x |
- |
- |
x |
- |
1/ Following stand test, the above inspection standards shall apply in addition to the acceptance standard of Table II.
2/ If it is impossible to determine source of the stain by thorough engineering and laboratory tests, excluding dissection, a stain of 1 inch maximum diameter or equivalent area is allowable, except self-sealing fuel cells, provided there is not greater than one such stain per 150 square feet of cell area.
19