MIL-STD-801D
TABLE IV. Additional criteria for dissection tested fuel cells. 1/
Item |
Defects |
Defect Classes |
Types of Fuel Cells |
||||
Minor |
Major |
Critical |
Bladder Cells |
Self- sealing Cells |
Crash Resistant Cells |
||
1 |
ADHESION OF INNER LINER TO SEALANT OR ADJACENT PLY IN FLAT PANEL AREAS IS LESS THAN 6 LBS. PER INCH WIDTH 2/ |
- |
x |
- |
x |
x |
x |
2 |
ADHESION OF INNER LINER TO CHAFING STRIPES IS LESS THAN 6 LBS. PER INCH OF WIDTH 2/ |
- |
x |
- |
x |
x |
x |
3 |
ADHESION OF FITTING FLANGE TO INNER PLY IS LESS THAN 6 LBS. PER INCH WIDTH 2/ |
- |
x |
- |
x |
x |
x |
4 |
ADHESION OF INSIDE AND OUTSIDE ACCESSORIES IS LESS THAN DESIGN VALUES 2/ |
- |
x |
- |
x |
x |
x |
5 |
DISSECTION OF FITTING FLANGE INDICATES CONSTRUCTION IS NOT IN ACCORDANCE WITH APPROVED MANUFACTURING SPECIFICATIONS |
- |
x |
- |
x |
x |
x |
6 |
ADHESION OF FABRIC FITTING FLANGES TO METAL RINGS IS LESS THAN 150 LBS. PER INCH OF WIDTH 2/ 3/ |
- |
x |
- |
x |
x |
x |
1/ Following dissection test, the above inspection standards shall apply in addition to the acceptance standards of Table
II.
2/ Test Method: ASTM D751, dry pull at 2 inches per minute. This factor also used for sampling tests of replacement fittings.
3/ Failure of fabric flange prior to adhesion failure does not constitute a defect.